MEGAPULSE SPECIFICATION
- Index:
- Megapulse Mk.5 specification
- Megapulse Mk.4 ver. 2 specification
- Megapulse Mk.4 ver. 1 specification
-
Megapulse Mk.5 - complete specification
-
Megapulse Mk.4 - complete specification
-
Megapulse Mk.5 - IP67 waterproof test certification
- Shipping dimensions
Megapulse specification (Mk.5 universal)
Voltage range | Battery | Mode of operation | |||
---|---|---|---|---|---|
Low | High | Voltage | Constant | Window | High |
0.0 v | 4.5 v | 6 v | power down | ||
4.5 v | 5.3 v | 6 v | suspend operation | ||
5.3 v | 6.4 v | 6 v | ✓ | ✓ | |
6.4 v | 8.0 v | 6 v | ✓ | ✓ | |
8.0 v | 10.5 v | 12 v | suspend operation | ||
10.5 v | 12.8 v | 12 v | ✓ | ✓ | |
12.8 v | 16.0 v | 12 v | ✓ | ✓ | |
16.0 v | 21.0 v | 24 v | suspend operation | ||
21.0 v | 25.6 v | 24 v | ✓ | ✓ | |
25.6 v | 30.5 v | 24 v | ✓ | ✓ | |
30.5 v | 31.5 v | 36 v | suspend operation | ||
31.5 v | 38.4 v | 36 v | ✓ | ✓ | |
38.4 v | 41.9 v | 36 v | ✓ | ✓ | |
41.9 v | 42.0 v | 48 v | suspend operation | ||
42.0 v | 51.2 v | 48 v | ✓ | ✓ | |
51.2 v | 65.0 v | 48 v | ✓ | ✓ |
Factory default setting | ✓ operates in this voltage range |
- Modes:
- In CONSTANT (LOW) mode, continuous operation in voltage range
- In WINDOW mode, operation suspended during battery charging (e.g. while engine operating)
- In HIGH mode, operation only during battery charging
Auto-selection of operating voltage:- Megapulse continuously senses the operating voltage, and presumes the battery voltage as shown in the table above
- At 80% DOD, operation is suspended grey lines in table. A further voltage drop transitions to a lower battery voltage
- As the voltage increases, the reverse process occurs as each voltage range is traversed
- The mode selected using the 'Mode' button will be remembered during transitions from one voltage range to another
Built-in tests:
Built-in test | Test procedure | Fail | Pass |
Load | 30A load applied, check volt drop after 5ms | Vdrop > 2v | Vdrop < 2v |
Batt V | Measured every 30 secs |
Physical dimensions
DESCRIPTION | SIZE (mm) | WEIGHT (kg) |
Megapulse unit: | 92 x 52 x 17 | 0.120 |
Megapulse mounting hole (4mm dia) spacing: | 78 x 38 |
- Performance:
- Battery maintenance (normal usage), maximum capacity: up to 2000 Ah
- Battery revival, maximum capacity: up to 1500 Ah
- Typical average power drain @: 6v: 6mA 12v: 9mA 24v: 8mA 36v: 5mA 48v: 5mA
- Data sheet:
Download the complete specification here
![]() |
Megapulse specification (Mk.4 ver.2)
Model | Voltage thresholds | Built-in tests | ||||
---|---|---|---|---|---|---|
Mk.4 | Low | High | Window | Load | 80% DOD | Batt V |
Vcutoff | Vthresh | Vwindow | Vsoc | |||
6 v | 5.3 v | 5.6 v | ✓ | |||
12 v | 10.5 v | 12.8 v | ✓ | ✓ | ||
24 v | 21.0 v | 25.6 v | ✓ | ✓ | ||
36 v | 32.0 v | 38.4 v | 33.6 v | ✓ | ||
48 v | 42.5 v | 51.2 v | 44.8 v | ✓ |
Factory default setting | ✓ test implemented |
- Modes:
- In LOW mode, Megapulse powers down below Vcutoff
- In HIGH mode, Megapulse powers down below Vcutoff and suspends operation below Vthresh
- In WINDOW mode, Megapulse powers down below Vcutoff and suspends operation above Vwindow
- Use magnet to switch Megapulse between modes: Low (green LED) and High / Window (red LED).
Magnet is effective only when Megapulse is operating.
Power-up and auto on/off:- After power down, Megapulse automatically starts operation above Vcutoff
- After power down, Megapulse always powers up in default mode
- After suspension, Megapulse resumes operation automatically in the same mode as before
Flashing LED significance:- 6v, 36v, 48v battery status: OK (green LED), 80% DOD warning (red LED) at Vsoc
12v, 24v previous load test: OK (green LED), failed (red LED) - red+green LEDs flash every 30 secs: performing voltage check
Built-in tests:
Built-in test | Test procedure | Fail | Pass |
Load | 30A load applied, check volt drop after 5ms | Vdrop > 2v | Vdrop < 2v |
80% DOD | Determined from the battery voltage | < Vsoc | > Vsoc |
Batt V | Shut down if battery voltage drops below | < Vcutoff | > Vcutoff |
Physical dimensions
DESCRIPTION | SIZE (mm) | WEIGHT (kg) |
Megapulse unit: | 100 x 58 x 21 | 0.180 |
Megapulse mounting hole (3.5mm dia) spacing: | 85 x 40 |
- Performance:
- Battery maintenance (normal usage), maximum capacity: up to 1500 Ah
- Battery revival, maximum capacity: up to 1000 Ah
- Typical average power drain: 6v: 36mA 12v: 18mA 24v: 9mA 36v: 9mA 48v: 11mA
- Data sheet:
Download the complete specification here
![]() |
Megapulse specification (Mk.4 ver.1)
Model | Voltage thresholds | Built-in tests | ||||
---|---|---|---|---|---|---|
Mk.4 | Low | High | Load | 80% DOD | Batt V | |
Vcutoff | Vthresh | Vsoc | ||||
6 v | 5.3 v | 5.6 v | ✓ | |||
12 v | 10.5 v | 12.8 v | ✓ | ✓ | ||
24 v | 21.0 v | 25.6 v | ✓ | ✓ | ||
36 v | 32.0 v | 38.4 v | 33.6 v | ✓ | ||
48 v | 42.5 v | 51.2 v | 44.8 v | ✓ |
Factory default setting | ✓ test implemented |
- Modes:
- In LOW mode, Megapulse powers down below Vcutoff
- In HIGH mode, Megapulse powers down below Vcutoff and suspends operation below Vthresh
- Use magnet to switch Megapulse between modes: Low (green LED) and High (red LED).
Magnet is effective only when Megapulse is operating.
Power-up and auto on/off:- After power down, Megapulse automatically starts operation above Vcutoff
- After power down, Megapulse always powers up in default mode
- After suspension, Megapulse resumes operation automatically in the same mode as before
Flashing LED significance:- 6v, 36v, 48v battery status: OK (green LED), 80% DOD warning (red LED) at Vsoc
12v, 24v previous load test: OK (green LED), failed (red LED) - red+green LEDs flash every 30 secs: performing voltage check
Built-in tests:
Built-in test | Test procedure | Fail | Pass |
Load | 30A load applied, check volt drop after 5ms | Vdrop > 2v | Vdrop < 2v |
80% DOD | Determined from the battery voltage | < Vsoc | > Vsoc |
Batt V | Shut down if battery voltage drops below | < Vcutoff | > Vcutoff |
- Performance:
- Battery maintenance (normal usage), maximum capacity: up to 1500 Ah
- Battery revival, maximum capacity: up to 1000 Ah
- Typical average power drain: 6v: 36mA 12v: 18mA 24v: 9mA 36v: 9mA 48v: 11mA
![]() |