X
megaintro(type: gif)
pulse(type: gif)

MEGAPULSE SPECIFICATION



Megapulse specification   (Mk.5 universal)

Voltage range Battery Mode of operation
Low High Voltage Constant Window High
0.0 v 4.5 v 6 v power down
4.5 v 5.3 v 6 v suspend operation
5.3 v 6.4 v 6 v
6.4 v 8.0 v 6 v
8.0 v 10.5 v 12 v suspend operation
10.5 v 12.8 v 12 v
12.8 v 16.0 v 12 v
16.0 v 21.0 v 24 v suspend operation
21.0 v 25.6 v 24 v
25.6 v 30.5 v 24 v
30.5 v 31.5 v 36 v suspend operation
31.5 v 38.4 v 36 v
38.4 v 41.9 v 36 v
41.9 v 42.0 v 48 v suspend operation
42.0 v 51.2 v 48 v
51.2 v 65.0 v 48 v

Factory default setting operates in this voltage range
Built-in test Test procedure Fail Pass
Load 30A load applied, check volt drop after 5ms    Vdrop > 2v    Vdrop < 2v
Batt V Measured every 30 secs
  • DESCRIPTION SIZE (mm) WEIGHT (kg)
    Megapulse unit: 92 x 52 x 17 0.120
    Megapulse mounting hole (4mm dia) spacing: 78 x 38

    top



    Megapulse specification   (Mk.4 ver.2)

    Model Voltage thresholds Built-in tests
    Mk.4 Low High Window Load 80% DOD Batt V
    Vcutoff Vthresh Vwindow Vsoc
    6 v 5.3 v 5.6 v
    12 v 10.5 v 12.8 v
    24 v 21.0 v 25.6 v
    36 v 32.0 v 38.4 v 33.6 v
    48 v 42.5 v 51.2 v 44.8 v

    Factory default setting test implemented
    Built-in test Test procedure Fail Pass
    Load 30A load applied, check volt drop after 5ms    Vdrop > 2v    Vdrop < 2v
    80% DOD Determined from the battery voltage < Vsoc > Vsoc
    Batt V Shut down if battery voltage drops below < Vcutoff > Vcutoff
  • DESCRIPTION SIZE (mm) WEIGHT (kg)
    Megapulse unit: 100 x 58 x 21 0.180
    Megapulse mounting hole (3.5mm dia) spacing: 85 x 40
    top



    Megapulse specification   (Mk.4 ver.1)

    Model Voltage thresholds Built-in tests
    Mk.4 Low High Load 80% DOD Batt V
    Vcutoff Vthresh Vsoc
    6 v 5.3 v 5.6 v
    12 v 10.5 v 12.8 v
    24 v 21.0 v 25.6 v
    36 v 32.0 v 38.4 v 33.6 v
    48 v 42.5 v 51.2 v 44.8 v

    Factory default setting test implemented
    Built-in test Test procedure Fail Pass
    Load 30A load applied, check volt drop after 5ms    Vdrop > 2v    Vdrop < 2v
    80% DOD Determined from the battery voltage < Vsoc > Vsoc
    Batt V Shut down if battery voltage drops below < Vcutoff > Vcutoff
    top